Medical infection control & pharmacy automation

AER 2025 Automatic Endoscope Reprocessor ISO 15883-4:2018
Automatic Endoscope Reprocessors

AER 2025 Automatic Endoscope Reprocessor

2025 automatic endoscope reprocessor with smart leak testing, channel monitoring, sterile-water final rinse and a 15-minute cycle, available with one or two tanks.

✓ ISO 15883-4:2018 ✓ GB 30689-2014
OVERVIEW

The 2025 model for fast, safe endoscope reprocessing

2025 model. The AER 2025 automatic endoscope reprocessor is designed and developed according to ISO 15883-4:2018 and GB 30689-2014. It automates washing, disinfection, final rinse and drying for flexible endoscopes, completing a standard cycle in around 15 minutes.

Scope protection design

  • Smart leak test: intelligent pressure control reduces false leak alarms caused by temperature changes. The test runs before the scope contacts liquid and monitoring continues throughout the cycle; a leak triggers visual and audible alarms and stops the program automatically.
  • Channel monitoring: independent monitoring of each endoscope channel improves cleaning and disinfection reliability and helps prevent scope damage.
  • Self-disinfection: a dedicated program disinfects the 0.2 μm water filter, tanks, chambers, pipes and hoses after maintenance, repair or interruption of use.
  • Traceability: real-time printing records the scope, operator, date, processing times, enzyme status and disinfectant conditions; scan-to-login identifies the operator.

High-efficiency washing and disinfection

AER 2025 chamber with rotating spray and channel connections
  • A rotating spray arm at the top cleans the outer surface of the endoscope from multiple directions.
  • Circulating water flow cleans and disinfects all inner channels.
  • A lumen booster pump continuously cleans the air/water and biopsy/suction channels, helping prevent biofilm formation.
  • Final rinse water passes through a built-in 0.2 μm filter to avoid secondary contamination after soaking.
  • Channels are dried by air and alcohol drying.

Fast, compatible reprocessing

Wash, rinse, soak, final rinse and dry are completed in around 15 minutes. The processor is compatible with common disinfectants including glutaraldehyde (GA), ortho-phthalaldehyde (OPA), peracetic acid (PAA) and chlorine dioxide.

Safe and easy to use

  • One-touch start; default programs can be adjusted to the department's requirements.
  • Transparent tempered-glass automatic door with foot switch for hands-free opening.
  • Fully enclosed tank design reduces disinfectant odor and improves operator safety.
  • Android control system and high-definition color touchscreen show program parameters and working steps in real time.
  • Automatic disinfectant addition and discharge; pour disinfectant into the tank and start the program.

Models and technical parameters

ItemNQX-1NQX-S1NQX-S3
Tank number122
DisinfectantMultiple useMultiple useSingle use
Dimensions630×760×1310 mm1260×760×1310 mm1260×760×1310 mm
Weight100 kg160 kg160 kg
Power220 V 50 Hz220 V 50 Hz220 V 50 Hz
Rated power2.2 kW2.2 kW2.2 kW
Water supplyPressure 0.2–0.5 MPa; flow ≥15 L/min; purified water
Drain≥Φ30 mm≥Φ30 mm≥Φ30 mm

Optional sterile gas generator

Sterile gas generator for endoscope reprocessing

The sterile gas generator combines a 0.01 μm high-precision filtration system with an air compression system. It supplies clean, sterile compressed air for air injection and drying, and can be used with automatic or manual scope washing tanks.

Models, tank configuration and options are selected according to endoscope volume, room layout and local water/air services. Confirm final specifications with Laoken.
KEY FEATURES

What makes this system different

01

Smart leak test with continuous monitoring

02

Independent endoscope channel monitoring

03

Rotating spray arm and lumen booster pump

04

Final rinse with built-in 0.2 μm sterile filter

05

Air and alcohol drying for channels

06

Android touchscreen with traceability and scan login

ADVANTAGES

Operational advantages

  • ✓Reprocessing completed in around 15 minutes
  • ✓Automatic self-disinfection of tanks, pipes, filters and hoses
  • ✓Compatible with GA, OPA, PAA and chlorine dioxide
  • ✓Automatic door and foot switch for hands-free operation
  • ✓Fully enclosed tank reduces disinfectant odor
  • ✓Single-tank, two-tank and single-use disinfectant models
APPLICATIONS

Where it is used

Endoscopy centresOperating roomsCentral sterile supply departmentsGastroenterologyRespiratory endoscopy
TECHNICAL SPECIFICATIONS

Configuration at a glance

ModelsNQX-1, NQX-S1, NQX-S3
Tank number1 / 2 / 2
DisinfectantMultiple use / multiple use / single use
Dimensions630×760×1310 / 1260×760×1310 / 1260×760×1310 mm
Weight100 / 160 / 160 kg
Power220 V 50 Hz, 2.2 kW
Water supply0.2–0.5 MPa, ≥15 L/min, purified water
Drain≥Φ30 mm
StandardsISO 15883-4:2018, GB 30689-2014
Cycle timeApproximately 15 minutes
CERTIFICATIONS & STANDARDS

Documented quality

✓

ISO 15883-4:2018

✓

GB 30689-2014

Certification scope varies by product and market. Contact us for the current certificate package.